In the drawings below, we show two typical and useful applications. The first is a silence latch.
Terminal A supplies +V to operate a Sonalert when some alarm condition occurs. The relay logic
pack and a normally open momentary switch are connected as shown. When the alarm

condition occurs, the Sonalert will sound. If the silence switch is then pressed, the Sonalert will
cease sounding and remain silent until the alarm condition resets (+V is removed from terminal
A). The silence latch will then automatically reset.

The second drawing shows a latching alarm used with a lock status sensing electric lock such as

Securitron's Magnalock. Terminal "LS" is the lock status output which supplies +V when the
lock is secure
. With the connections as shown below, the alarm will sound any time the lock
becomes insecure (+V is removed from terminal LS). Even after the lock has been made secure
again, the alarm will continue to sound until the momentary reset switch is pressed.

FIG. 3: LATCHING CIRCUITS

RELAY
LOGIC
PACK

BLACK

ORANGE

GREEN

BROWN

RELAY
LOGIC
PACK

BLACK

ORANGE

BLUE

BROWN

COM

NO

COM

NO

YELLOW

SONALERT

A

SILENCE SWITCH

+

LS

SONALERT

RESET SWITCH

VIOLET

YELLOW

SILENCE LATCH CIRCUIT

LATCHING ALARM CIRCUIT W/ LOCK STATUS

6. DPDT RELAY
The relay logic pack can be employed as a double pole double throw 2 Amp relay by use of the
following wires:
Orange = + coil

Brown = COM1

Green = NC1

Yellow = NO1

Black = - coil

Blue = COM2

Violet = NC2

Gray = NO2

7. SCHEMATIC
The relay logic pack's schematic is shown below to permit the user to evaluate other
applications.

FIG. 4: RELAY LOGIC PACK SCHEMATIC

RED

BLACK

ORANGE

GREEN

BROWN

YELLOW

R1

R2

C1

C2

B

NC2B

NO2B

WHITE

BLUE

VIOLET

GRAY

C1

A

NC1A

NO1A

C1

B

NC1B

NO1B

C2

A

NC2A

NO2A

C1A, NC1A, NO1A, C1B, NC1B, NO1B

R1 = DPDT RELAY COIL FOR CONTACTS:

R2 = DPDT RELAY COIL FOR CONTACTS:
C2A, NC2A, NO2A, C2B, NC2B, NO2B

C1 = DELAY CAPACITOR

8. MAGNACARE

LIFETIME REPLACEMENT WARRANTY

For warranty information visit:

www.securitron.com/en/site/securitron/About/MagnaCare-Warranty/

Advertising