relay is showing 'off'. Why doesn't it turn on?" The answer is that the DT-7 does not check
what time it is and then look to see if it is "supposed" to be on or off. It just advances its clock,
minute by minute, and when it encounters an instruction, it executes the instruction. On initial

set-up, use the test button to put the unit in the desired initial state.

If an on and off instruction both occur at exactly the same time and day, the off instruction
will be executed and the on instruction will be ignored
. An instruction is erased by
incrementing the hours, minutes, and day buttons to restore the horizontal (null) lines. Note

that momentarily pressing the reset detent will eliminate all program data from the unit as well
as eliminating the time setting. The reset detent has the same effect as removing all power
(including the battery) from the unit.

FIG. 2: TIME SETTING AND PROGRAMMING

Timer

Day

h+

m+

Timer

Day

h+

m+

DAY OF WEEK

MODULE STATUS

HOLD DOWN

TO SET TIME

INCREMENTS DAYS

TEST BUTTON: MANUALLY

CHANGES MODULE STATUS

(ON OR OFF)

TIME OF DAY

INCREMENTS
MINUTES

INCREMENTS
HOURS

DISPLAY MODULE: OPERATING MODE AND TIME SETTING

DISPLAY MODULE: PROGRAMMING MODE

INSTRUCTION
FOR SATURDAY

AND SUNDAY

TIME RELAY WILL

OPERATE (4:40 PM)

INCREMENTS DAYS AND

CALLS UP BLOCK PROGRAMMING

RETURN TO

OPERATING MODE

PRESS TO ENTER

PROGRAMMING

MODE AND TO

INCREMENT

INSTRUCTIONS

1 0F 6

INSTRUCTIONS

TO OPERATE RELAY

AT PROGRAMMED

TIME AND DAY

16:40

SA SU

TIMER

1 ON

WE

OFF

11:05

Reset

ERASES TIME

AND PROGRAM

Reset

BLOCK

INCREMENTS
MINUTES

INCREMENTS
HOURS