3 adjust the load limiter – Harrington Hoists and Cranes (N)ER Load Limiter - ((N)ER1) User Manual
Page 15

14
4.2.3
After Load Limiter installation:
If the LL is to be adjusted after installation on to the hoist, then determine the SSL using f and the hoist’s RC
from Table 4-1.
Table 4-1
Rated Capacity
Hoist
Capacity Code*
Load Limiter Type
LL
(lbs.)
Hoist
(Tons)
f
001H
01H
99
1/8
1.55
003S
03S
198
1/4
1.45
005L
05S
397
1/4
1.30
003H
03H
198
1/4
1.65
005S
05S
397
1/2
1.30
010L
010M
010S
10S
794
1
1.30
015S
15 M
972
1.5
1.15
020L
020M
020S
20S
1296
2
1.30
025S
25M
1620
2.5
1.25
030C
30R
3307
1.10
030L
030S
30S
1944
3
1.10
050L
50R
5512
5
1.10
*Refer to ER/NER and SNER Owner’s Manual.
4.3
Adjust the Load Limiter
4.3.1
Refer to Figure 4-1.
4.3.2
Remove the LL’s case cover.
4.3.3
Loosen the setscrew with a hex wrench and Rotate the adjuster clockwise to obtain a sufficient gap
between the adjuster and the elec trical switch plunger.
4.3.4
Apply the Static Set Load determined in section 4.2 above.
4.3.5
Rotate the adjuster counter clockwise until the electrical switch is activated or clicks to make contact. A
circuit tester may be used to verify the making of contact.
4.3.6
Tighten the setscrew to lock the adjuster to the plunger arm.
4.3.7
Test the LL setting. Place a test load equivalent to the Set Point Load (RC X SP) on the floor directly
beneath the hoist. Connect the load to the hoist’s bottom hook such that there is no slackness in the hoist’s
load chain. Operate the hoist in the up direction to verify that the Load Limiter actuates and prevents the
hoist from lifting the load. Readjust if necessary.