3.6

Power Source



For crane systems requiring electrical power, ALWAYS provide crane runways

with Class 3 grounding. Failure to provide an electrical ground in accordance with industry
standards and local codes could result in electric shock. NEVER paint any wheels or wheel
running surfaces in order to ground the crane properly.



Provide electrical power to the crane and any powered components in accordance

with applicable industry standards, local codes, and manufacturer's requirements. Sections 3.6.1 and
3.6.2 below provide general guidelines for typical configurations.

3.6.1

Power supply with enclosed conductors. (See Figure 3-17)

1 1

I n c h e s

2

I n c h e s

1 1 - 1 5 . 5

I n c h e s

N o . 5 2 7

C o l l e c t o

B r a c k e t

A s s e m b

1 I n c h

S q u a r e

B a r

6

I n c h e s

1 1

I n c h e s

6 t o 7 I n c h

1 I n c h

S q u a r e

B a r

N o . 5 2 7 1 1 C o l l

B r a c k e t A s s e m b

Figure 3-17 Collector Bracket Assembly Mounting

3.6.2

Power supply with festooned cable. (See Figure 3-18)

Bridge Guide

Wire

Electric

Hoist

Hoist Power Cable

Crane Power Cable

Power Source

Crane Guide Wire

Terminal Box

End Truck

Bridge Beam

Crane Runway

Figure 3-18 Typical Festoon Cable System