Part 4, Heater piping, A. general piping information – HTP 199-55SA User Manual

Page 15: Part 4 – heater piping

Advertising
background image

15

LP-179 REV. 3.21.14

COLD WEATHER HANDLING

– If the heater has been stored in a very cold location (BELOW 0

o

F) before installation, handle with care

until the plastic components come to room temperature.

Remove all sides of the shipping crate to allow the heater to be lifted into its installation location.

PERFORMANCE SPECIFICATIONS FOR PHOENIX MODELS

BTUH

Efficiency

Temperature Rise

(°F)

40

50

60

70

80

90

100

110

120

130

140

(°C)

22

28

33

39

44

50

56

61

67

72

78

100,000

96%

GPH

298

240

202

173

152

136

123

110

101

94

88

GPM

5

4

3.4

2.9

2.5

2.25

2

1.8

1.7

1.6

1.5

LPH

1128

908

765

655

575

515

466

416

382

356

333

LPM

18.8

15.1

12.75

10.9

9.6

8.6

7.8

6.9

6.4

5.9

5.6

130,000

96%

GPH

384

309

260

222

195

175

158

141

130

120

112

GPM

6.4

5.2

4.3

3.7

3.25

2.9

2.6

2.4

2.2

2

1.9

LPH

1454

1170

984

840

738

662

598

534

492

454

424

LPM

24.25

19.5

16.4

14

12.3

11

10

8.9

8.2

7.6

7

160,000

96%

GPH

470

378

317

271

238

213

192

173

159

147

137

GPM

7.8

6.3

5.3

4.5

4

3.6

3.2

2.9

2.7

2.5

2.3

LPH

1779

1431

1200

1026

901

806

727

655

602

556

519

LPM

29.7

23.9

20

17.1

15

13.4

12.1

10.9

10

9.3

8.7

199,000

96%

GPH

582

468

392

335

294

263

237

213

196

181

169

GPM

9.7

7.8

6.5

5.6

4.9

4.4

4

3.6

3.3

3

2.8

LPH

2203

1772

1484

1268

1113

996

897

806

742

685

640

LPM

36.7

29.5

24.7

21.1

18.6

16.6

15

13.4

12.4

11.4

10.7

Table 2

– Recovery on rating plate is based at 94% thermal efficiency at 70

o

Fahrenheit rise, as required by ANSI

PERFORMANCE EQUATIONS


Rated Input x .9

GPM = Temp Rise (

o

F) x 500

GPH = GPM x 60

PART 4 – HEATER PIPING

Failure to follow the instructions in this section WILL VOID the warranty and may result in property damage, serious injury, or death.

DO NOT pipe this water heater with black iron, galvanized steel, steel, or lead pipe. Doing so will result in premature product failure and
property damage, and WILL VOID the product warranty.

A. GENERAL PIPING INFORMATION

Use two wrenches when tightening water piping at heater. Use one wrench to prevent the heater return or supply line from turning.
Failure to prevent piping connections from turning could cause damage to heater components.

The heater control module uses temperature sensors to provide both high limit protection and modulating temperature control. The
control module also provides low water protection by sensing the water level in the tank. Some codes/jurisdictions may require
additional external controls.

Never use dielectric unions or galvanized steel fittings when connecting to a stainless steel storage tank or heater. Use only copper or
brass fittings. Teflon thread sealant must be used on all connections.