5. Maintenance inspection
55
2) Loosen the deceleration belt.
Loosen the bolt fixing the motor bracket using the hexagon wrenches with the distance to
the opposite side of 3 mm and 4 mm. Then, slide the belt until the pulley is turned without
making any contact.
Use of Hexagon Wrench with the
Distance to the Opposite Side of 3 mm
Use of Hexagon Wrench with the
Distance to the Opposite Side of 4 mm
3) Remove the deceleration belt.
4) Attach the new deceleration belt manually.