1. Specifications Check

19

1.3 Operating conditions

1.3.1 Available Conditions for Operation

When selecting a desired model of shaft-type linear servo actuator, you must ensure that the

selected actuator satisfies the following two conditions.

[Condition 1]

The thrust required for acceleration must not exceed the maximum thrust of the shaft-type linear

servo actuator.

[Condition 2]

The thrust during continuous operation must not exceed the rated thrust of the shaft-type linear

servo actuator.

The above conditions are explained by using a trapezoid operation as an example.

Speed

Time

ta

tf

td

t

The above operation pattern can be expressed differently in a graph where the vertical axis

represents thrust.

Thrust

Time

ta

tf

td

t

Fa

Fd

Ff

t : Operation time per cycle

(sec)

ta : Acceleration time (sec)

tf : Moving time at constant

speed (sec)

td : Deceleration time (sec)

Fa : Thrust required for

acceleration (N)

Ff : Traveling resistance (N)

Fd : Thrust required for

deceleration (N)