IAI America E-Con User Manual

Page 27

Advertising
background image

19

2. X-SEL-J/K/P/Q/JX/KX/PX/QX

(2) Factory-set parameters for P/Q types

No.

Parameter name

Input range

Setting

Remarks

1

I/O port assignment type

0 ~ 20

0

0: Fixed assignment
1: Automatic assignment (Priority: Assigned

from slot 1)

* Ports are assigned consecutively only for

slots where a board is physically installed,
starting from slot 1, for safety reasons.

2

Input port start number for standard I/O
based on fixed assignment (I/O1)

-1 ~ 599

-1

0 + (multiple of 8) (Invalid, if a value is entered
with a negative sign.)

3

Output port start number for standard
I/O based on fixed assignment (I/O1)

-1 ~ 599

-1

300 + (multiple of 8) (Invalid, if a value is
entered with a negative sign.)

4

Input port start number for expansion
I/O1 based on fixed assignment (I/O2)

-1 ~ 599

-1

0 + (multiple of 8) (Invalid, if a value is entered
with a negative sign.)
(Slot immediately next to the standard I/O slot)

5

Output port start number for expansion
I/O1 based on fixed assignment (I/O2)

-1 ~ 599

-1

300 + (multiple of 8) (Invalid, if a value is
entered with a negative sign.)

6

Input port start number for expansion
I/O2 based on fixed assignment (I/O3)

-1 ~ 599

-1

0 + (multiple of 8) (Invalid, if a value is entered
with a negative sign.)

7

Output port start number for expansion
I/O2 based on fixed assignment (I/O3)

-1 ~ 599

-1

300 + (multiple of 8) (Invalid, if a value is
entered with a negative sign.)

8

Input port start number for expansion
I/O3 based on fixed assignment (I/O4)

-1 ~ 599

-1

0 + (multiple of 8) (Invalid, if a value is entered
with a negative sign.)

9

Output port start number for expansion
I/O3 based on fixed assignment (I/O4)

-1 ~ 599

-1

300 + (multiple of 8) (Invalid, if a value is
entered with a negative sign.)

10 Error monitor for standard I/O (I/O1)

0 ~ 5

0

11 Error monitor for expansion I/O1 (I/O2)

0 ~ 5

0

12 Error monitor for standard I/O2 (I/O3)

0 ~ 5

0

13 Error monitor for expansion I/O3 (I/O4)

0 ~ 5

0

0: Do not monitor
1: Monitor
2: Monitor (Do not monitor 24-V I/O power

supply errors)
(Main application version 0.55 or
later)

3: Monitor (Monitor 24-V I/O power supply

errors only)
(Main application version 0.55 or
later)

14 Number of ports used for remote input

via network I/F card

0 ~ 256

64

Multiple of 8

15 Number of ports used for remote

output via network I/F card

0 ~ 256

64

Multiple of 8

16 Input port start number for network I/F

module based on fixed assignment

-1 ~ 599

0

0 + (multiple of 8) (Invalid, if a value is entered
with a negative sign.)

17 Output port start number for network

I/F module based on fixed assignment

-1 ~ 599

300

300 + (multiple of 8) (Invalid, if a value is
entered with a negative sign.)

18 Error monitor for network I/F module

0 ~ 5

1

0: Do not monitor
1: Monitor
* Some exceptions apply.

I/O1 through I/O4 indicate slot numbers.