IAI America CON-TG User Manual

Page 46

Advertising
background image

36

6.

Operation:

Mode

Flow

Chart

- It defines the zone where the zone output signal of the standard type turns

ON.

Individual setting is available for each target position to give flexibility.

No.

Position

[mm]

Zone+

[mm]

Zone-

[mm]

Comment

0

5.00

100.00

0.00

Backward

end

1

380.00

400.00

300.00

Forward

end

2

200.00

250.00

150.00

Midpoint

Movement command to backward end

Movement command to forward end

Movement command to midpoint

- It defines the acceleration/deceleration characteristics.

The default value is 0.

0: Trapezoid pattern

1: S-shaped motion

2: First-order delay filter

Trapezoid pattern

* Set the acceleration and deceleration in the “Acc” and “Dcl” fields of the position

table.

[Setting example]

Home

Zone output signal

Backward

end

+ side limit

Zone output signal

Forward

end

Zone output signal

Midpoint

Speed

Acceleration

Deceleration

Time

(8) Zone +/-:

(9) Acc/Dcl Mode:

Advertising
This manual is related to the following products: