Logic 107:partial stop logic for various apparatus, Operation example (logic 107) – IDEC FS1A Controller User Manual

Page 332

Advertising
background image

LOGIC

5-284

Logic 107: Partial stop logic for various apparatus

Overview (Logic 107)

This logic is for safety protective measures applicable to production machines and robots. Safety
outputs perform as single channel outputs.
This logic enables the connection of 5 dual channel direct opening inputs.

Hazardous Area A

Safety input 1

Safety input 2
Safety input 3

Safety output 1

Safety input 4
Safety input 5

Safety output 2

System runs

System runs

Hazardous Area B

Logic 107

Safety
output 1-1

Safety
output 2-2

Safety
output 1-2

Safety
output 2-1

Emergency
stop switch

Safety switch

Operation example (Logic 107)

●Partial system stop <Hazardous Area A> ●Partial system stop <Hazardous Area B>

Open!

System stops

System runs

Safety input 1

Safety input 2
Safety input 3

Safety output 1

Safety input 4
Safety input 5

Safety output 2

Hazardous Area A

Hazardous Area B

Open!

Safety input 1

Safety input 2
Safety input 3

Safety output 1

Safety input 4

Safety input 5

Safety output 2

System runs

System stops

Hazardous Area A

Hazardous Area B

●Entire system stops <Hazardous Area A, B>

Safety input 1

Safety input 2
Safety input 3

Safety output 1

Safety input 4
Safety input 5

Safety output 2

System stops

System stops

Hazardous Area A

Hazardous Area B

Press!