Equipment Setting and Caution

1. EP CONNECTION
1) When connecting with EP equipment, please connect the matrix terminal of EP and emergency
panel connection terminal by using the EP connector supplied as an accessory of the PX-6216.
2) Connect the audio signal of PRE OUT of EP to EP audio input terminal on the top of PX-6216.
Volume control of EP input can be set in the equipment setting of operation program.

2. TIMER CONNECTION
1) When connecting with TIMER, connect the Timer contact point input terminal of ECS-6216MS and
remote output terminal of Timer.
2) Connect the audio signal of channel out terminal of Timer to the Timer audio input terminal on the
top of PX-6216. Volume control of Timer input can be set in the equipment setting of operation
program.

3. DATA LINK IN/OUT CONNECTION
1) Connect the LINK IN terminal of PX-6216 and LINK OUT terminal of DIB-6000 with UTP cable
wired strait or direct method. Connect the DIB-6000 to PC by using USB cable.
2) Set the termination switch terminal of DIB-6000 to LOAD.

Communication error may occur if setup is incorrect.

3) Connect the other equipment including ECS-6216MS to each other through LINK IN/OUT terminal.
4) Set the TERMINATION switch of the last equipment in the data link to LOAD. Set the other
equipment to OPEN.