Rear panel – Inter-M PX-6216 User Manual

Page 8

Advertising
background image

Rear Panel

1. BGM INPUT TERMINAL


TYPE A

TYPE A

TYPE A

TYPE A

European Area

- INPUT 1 and 2 : Connection of BGM sources is possible via the 2 XLR
combo jack channels. Condenser microphones with 24V PHANTOM POWER
can be connected on channel 1 and 2. These inputs can select between
MIC/Line inputs through setting of operation programs.
- INPUT 3~8 : 6 XLR channels,
- INPUT 9~10 : 2 RCA stereo input jacks.


TYPE B

America

INPUT 1 and 2 :

Connection of BGM sources is possible via the 2 detachable

Euroblock terminals,

Condenser microphones with 24V PHANTOM POWER

can be connected on channel 1 and 2. These inputs can select between
MIC/Line inputs through setting of operation programs

- INPUT 3~8 :

BGM sources is possible via the 6 detachable Euroblock

terminals,

.

- INPUT 9~10 : 2 RCA stereo input jacks.

2. EMERGENCY AUDIO INPUT TERMINAL
Audio input terminal connecting the emergency panel unit (EP-9216, 9216V, 616, 6216) and allowa
priority broadcast from EP via contact connection terminal.

3. TIMER AUDIO INPUT TERMINAL
Audio input terminal connecting the TIMER (PW-9246,642,6242) allows priority broadcasting via
timer contact triggers.



4. REMOTE MIC COMMUNICATION TERMINAL
This terminal is used to directly connect RM-6024 remote paging microphones.
This port can be expanded to connect up to 8 paging microphones when connected to the RME-6108
Remote microphone extender.