MIXING AMPLIFIER

5

PMU-360N/480N/600N

7. MASTER VOLUME CONTROL

The master volume control to collectively control the sound level of all outputs and by turning the knob
clockwise to increase the volume and counterclockwise to decrease it.

8. POWER SWITCH

9. POWER INDICATOR

This LED Lights green when the unit is powered on.

10. ATTENUATOR

Built-in ATTENUATOR over zone 5, It allows to decrease the output volume independently from master volume.

※Caution : ZONE 5 is output terminal with ATTENUATOR function, and a recommended speaker is lower

than 50W(total impedance is upper than 200Ω). Please be careful of connecting the speakers.

11. ZONE SELECTION SWITCH

Use the zone selection switches to route the program audio from the amplifier output to speaker zone 1
through zone 5. The All button controls turns ON/OFF all zones. The Indicators lights on when zone
selection switches indicates if the zone is on.

12. LCD OPERATION DISPLAY

Displays the output level meter, each bar is marked in intervals of 3 to 5dB.

1) MENU MODE

<Menu Selection Screen>

- Menu selection screen will be shown by pressing and holding the select button, choose the menu by

turning the select knob to the right or left then select the desired menu by pressing select button briefly.

USB PLAYBACK MODE
USB Memory Playback, USB Audio Stream

Mode

100V Output

70V Output

Switch mode 1

100V

70V

Switch mode 2

70V

49V

Switch mode 3

50V

35V