STANDARD EQUIPMENT EXPLAINED

3’ HARD WIRED CABLE (TWO RED 10 AWG WIRES) (Fig.1 – B ) is to
be connected directly in-line with the provided adapters. This cable
features a 50-amp maxi fuse for protection. When the tool is used
properly, this Maxi fuse should never blow. The maxi fuse protects the
components should the PULSAR

accidentally be connected across the

battery terminals (positive and negative). DO NOT BYPASS THE MAXI
FUSE OR PLACE A LARGER FUSE INTO THE HOLDER OR THE
WARRANTY WILL BE VOIDED.

10’ HARD-WIRED GROUND CABLE (Fig.1 – E ) is to be connected to
a solid ground source, such as the engine or vehicle battery. This cable
grounds the onboard computer and enables the PULSAR

to run

continuously from the vehicle

s power source.

MINI/STANDARD ATC/ATO FUSE ADAPTER (TWO BLACK 12AWG
WIRES, 30 AMP MAX) (Fig.1 – I ) connect the PULSAR

directly to the

Fuse Box--ATC and ATO style Mini and Standard fuses. The Fuse
Adapter Master Kit is available for additional fuse box connector types.
(Please see the last page for additional features).


BATTERY CLIP ADAPTER (TWO RED 10AWG WIRES, 50 AMP MAX)
(Fig.1 – H ) also known as Alligator Clips, are used for Parasitic Draw
Testing and Bench Testing/power delivery only. These adapters are for
positive connections ONLY and should NEVER be connected to
ground.

BENCH TEST/VOLTAGE PROBE ADAPTER (10 FOOT SILICONE
INSULATED RED 17AWG WIRE, Sustained 10 AMPS and up to 20
AMPS in short duration.) (Fig.1 – U ) Needle point threaded voltage
probe and alligator clip for battery connection. Voltage probe plugs in-
line with PULSAR

for applying current while reading the amperage

draw.


5 FUSE BOX ADAPTERS: (TWO RED WIRE 10 AWG, 50 AMP Max)
(Fig.1 – P thru T) adapters for different vehicle applications (FLF, FLS,
Glass Style, European Ceramic, Female Spade Maxi, and Standard
Female Spade.)

SOFT CASE holds the PULSAR

and the adapters.

Advertising