Joyce DIA201 - ACME 1 diameter, .25" pitch, .50 lead"" User Manual

Page 13

Advertising
background image

13

3-5 Travel limit information

1. Translating tube integrated actuator

Translating tube minimum closed dimension = Rise” + 8 1/2”
Translating tube extended dimension = (Rise” x 2) + 8 1/2”
Maximum rise allowable is 24”
Minimum dimension and maximum dimensions are measured from base of
actuator to clevis eye.

2. Traveling nut integrated actuator

Traveling nut minimum closed dimension = Rise” + 5 7/8
Maximum rise allowable is 24”
Minimum dimension and maximum dimensions are measured from base of
actuator to end of the lifting screw.


3-6 Maintenance Log

Date

Maintenance Performed

Initials