OPERATION

REMOTE CONTACT CLOSURE - The SQ-1500 remote control terminal

can be connected to a contact closure for remote operation. (See Re-

mote Switch Connection) Any latching switch or relay will work for

this purpose. Juice Goose recommends use of a double throw device

in order to maintain one of two contact closures at all times. Com-

puter controlled devices such as those produced by Crestron, AMX

and similar companies may be used to control the SQ-1500.

SEQUENCE SWITCH - Without a contact closure on the remote con-

trol terminal the sequence switch on the front left of the SQ-1500 will

control its operation. In the event of a failure of the SQ-1500 timing

control circuit, the Manual On switch on the front of the chassis al-

lows activation of the SQ-1500. (Note: the Manual On option does not

provide sequencing).

REMOTE SWITCH CONNECTION

The following instructions are provided to assist with connection of a

latching remote switch or relay to the five position terminal on the

back of the SQ-1500 chassis.

SINGLE POLE DOUBLE THROW

LATCHING SWITCH









In the above illustration Position 1 on the terminal should be con-

nected to the common pole on the SPDT switch or relay. Positions 4

and 5 should be connected to the other two poles. Closing Position 1

to Position 4 will begin a sequence DOWN. Closing Position 1 to Posi-

tion 5 will begin a sequence UP.