MONITORING

Each SQ-1500 device has four LEDs on the chassis to allow real time

monitoring of the device’s performance. A green LED blinks to indicate

that the program on the processor chip is running and the control

circuitry is performing normally. Three red LEDs correspond to the

three Power Pods (i.e. sequence events). Each Pod LED lights to indi-

cate that a sequence stage has been completed and the correspond-

ing POD has power.

IN CASE OF MALFUNCTION

The Juice Goose SQ-1500 is ruggedly constructed and contains quality components. There
are no user serviceable parts inside the SQ-1500. Unauthorized service will void all exist-
ing warranties and may result in equipment damage and personal injury.

Should improper performance be observed consult the following guidelines for diagnosis.

SYMPTOMS AND SOLUTIONS.
1.

Unit will not turn on.

a. Check to see that main utility power is available.

b. Check that the circuit breaker on the SQ-1500 is not tripped.

c. Check the Processor LED on the chassis. If it is not lit the SQ-1500 is proba-

bly not receiving power. If it is lit but not flashing the SQ-1500 processor is not running.
Remove power. Then restore power to reset the processor.

d. If the device is being remotely activated:

i. Check the signal line leading to the SQ-1500 signal input. Discon-

nect the signal input cable and try to activate the product with the switch on the chassis.
If this works either the cable is bad or the device intended to remote control the SQ-1500
is failing to create the correct contact closure.

ii. Refer to the manual’s Remote Switch Connection sections.

2. Unit will not turn off.

a. It is likely that when a unit fails to turn off the cause is similar to that

which would cause a unit to fail to turn on.

b. Follow steps outlined in 1., above.

3. Unit turns itself off unexpectedly.

a. The unit may have encountered excessive current draw that caused the cir-

cuit breaker to trip. Examine the breaker. If it has tripped the button section of the
breaker will be extended and can be reset by pushing it in after the unit has been off for
a brief period.

b. Review the total current requirement of the equipment plugged into the SQ-

1500 to be certain it is less than fifteen amps. See the Detail Specification section of this
manual.

If the problem can not be remedied, if the encountered problem is not listed here and par-
ticularly if any evidence of severe or hazardous performance is observed, immediately
disconnect power to the SQ-1500 and contact your local Juice Goose dealer or Juice
Goose directly.

SERVICE

Should your unit require service, contact Juice Goose to receive a service authorization
number. This number will allow us to track your returned unit. Please note that no re-
turns will be accepted without such a number.

7320 Ashcroft, Suite 104 Houston, Texas 77081

(p) 713-772-1404 (f) 713-772-7360 (e) [email protected] www.juicegoose.com