GENERAL DESCRIPTION

The Juice Goose RT-15 is a 15 amp, rack mounted power dis-
tribution module that can be turned on and off locally and by
way of remote contact closure. It also features a dry contact
closure on power activation as well as optional, high perform-
ance AC power filtration and protection.

The device is intended for application where a) only a single
remote circuit needs to be controlled, b) emergency alarms
systems require an automatic turn on or turn off and/or c)
an output contact closure is required to trigger electronic
equipment that may be powered but is operating in a stand-
by mode.

CHASSIS FRONT FEATURES

Power Switch - As set up at the factory, the power switch on
the front controls the turn on and turn off of the RT-15. In
this configuration the internal low voltage switch lead is con-
nected to the “Switch” position on the RT-15 circuit board and
a wire jumper is attached across the “Input” terminals on the
back of the chassis. The switch will function ONLY in this
configuration.

Power On LED - This light will be illuminated green when the
RT-15 has been turned on.

External Fault
(Only with RX Series Line Conditioning Option) - This light will
be illuminated red in the event of a wiring fault outside the
RT-15. Such faults include open ground, faulty neutral connec-
tion and power line voltage in excess of 150 VAC. The RT-15
with optional line conditioning will not turn on under these
fault conditions.

Protection OK
(Only with RX Series Line Conditioning Option) - This light will
illuminate green when the RT-15 is turned on and there are no
line faults. In this condition the RT-15 will be providing AC line
surge protection and noise filtration.

AC Power Receptacle - Electric power is available from this
outlet whenever the RT-15 is plugged in. (See External Fault)

Advertising