CHASSIS BACK FEATURES

AC Power Cord - Insulated 14 AWG power cord with 15 amp
(NEMA 5-15P) plug

Circuit Breaker - 15 amp Thermal

Switched Receptacles (6) - These NEMA 5-15R duplex recepta-
cles are turned on and off with the local or remote control of
the RT-15

Unswitched AC Receptacle - Electric power is available from
this outlet whenever the RT-15 is plugged in. (See External
Fault)

Remote Control Terminals - Two position terminals allow dry
contact closure remote activation and contact closure output.

SET-UP & INSTALLATION

LOCAL CONTROL
The RT-15 is configured at the factory to allow power turn on
and off control with the switch on the front of the unit. This
local control is possible because of two default set up fea-
tures. First, there is a factory installed jumper across the re-
mote control “Input” terminal on the back of the chassis. Sec-
ond, inside the chassis a low voltage lead is attached to the
RT-15 circuit board in a position labeled, “SWITCHED”.

REMOTE CONTROL
For remote activation the low voltage lead on the RT-15 board
must be moved from the “SWITCHED” to the “ON” position.
(Failure to make this change will allow the switch on the front
of the chassis to turn the RT-15 off when it otherwise would
be on via remote control.)

Be sure the RT-15 is unplugged before opening the chassis for
any reason. To remove the chassis top remove the three
screws from each side of the chassis that hold the chassis
top in place. Carefully pull the chassis top up from the main
chassis assembly. Move the wire connected to the SWITCHED
position (J8) on the circuit board to the ON position (J6). This
will disconnect the switch from the power control circuit and
directly wire that portion of the circuit. Replace the chassis

top and secure with the six screws.