Whf installation instructions, Danger – King Electric Model WHF User Manual

Page 2

Advertising
background image

ELECTRIC SHOCK OR FIRE HAZARD

!

!

Figure 3

2

WHF INSTALLATION INSTRUCTIONS

CAUTION!

Turn OFF all electrical power

to install heater

Rating Label Location

Total Amps

Minimum AWG. Wire

Size (Copper

Circuit Breaker or

Fuse Size

0 thru 12

#14

15 amp

12.1 thru 16

#12

20 amp

16.1 thru 24

#10

30 amp

Minimum Clearances for heater:

Table 1

Front

TOP

BOTTOM

SIDES

36 in

12 in

4 in

6 in

0.9 m

30.5 cm

10.2 cm

15.2 cm

Selecting A Location For Your Heater:

DO NOT install less than 6” (15cm) from vertical side
walls or open edge of door. This heater must have an

unrestricted airflow. DO NOT select a location where it

is likely to be blocked by furniture, curtains, etc. Be

sure the location selected allows sufficient space for the

heater as shown by Table 1. DO NOT locate this heater

in an area where combustible vapors, gases liquids, or

excessive lint, dust or moisture is present.

The wire and breaker sizing chart will give a general rule

of installation size. Consult an electrician if you are not

knowledgeable about wiring codes.

Wire and Breaker Sizing:

Table 2

WIRING: Branch Circuit Connection

1. Connect heater only to the voltage, amperage and

frequency specified on the nameplate.

2. Wiring procedures and connections shall be in ac-

cordance with all National and local codes having

jurisdiction.

3. Set the bag containing the grille and packet with

two (2) grille screws aside.

4. Loosen mounting screw and remove fan heater as-

sembly.

5. A knockout of 1/2 inch conduit size (7/8 inch /

2.2cm) is provided in the back and side of the heater

for power to enter. Provide proper strain relief con-

nectors for your wire entering the wallbox.

6. Install wallbox a minimum of 6” from vertical side-

walls and 4” above floor.

The front edge of wall

can MUST extend 1/2” beyond finished wall sur-

face.

7. Secure wallbox to the 2 x 4 studs using the two (2)

holes on the side of the wallbox. Secure to wall stud

on opposite side if required.

8. Connect supply wires, attach ground feed wire to

the green ground wire with wire nuts.

9. Reinstall heater assembly into wallbox with screw at

top of interior.

10. Install grille securely with screws provided in pack-

et. Do not over tighten.

11. Test unit by turning thermostat up past room tem-

perature. You will see a puff of smoke as the ele-

ments are energized and the fan turns on. This is a

normal burn off of manufacturing lubricants and will

dissipate in 5 minutes.

12. Heater will continue to run until the room tempera-

ture you set is reached and then turn itself off until

the temperature drops again.

CAUTION - High temperature. Risk of fire, keep electri-

cal cords, drapery, furnishings, and other combusti-

bles at least 3 feet (0.9 m) from the front of the

heater as well as away from the side and rear. To

reduce the risk of fire, do not store or use gasoline or

other flammable vapors and liquids in the vicinity of the

heater.

Figure 2

Wiring Diagram Figure 5

Zero clearance to insulation.

Figure 4

!

DANGER

Advertising