6. Follow the desired wiring diagram, as shown in Figure 5, to
connect the power supply to the heater using approved wire
nuts.
NOTE: When accessories are installed, use wiring diagram sup-
plied with the accessory.
7. If front cover was removed, reinstall by hooking the top edge
on the support bracket(s). Then push down to latch onto the
support bracket(s).
8.Replace wiring compartment cover(s).
9.Follow instructions accompanying thermostat for installation
and wiring thermostat. Visit www.king-electric.com for typical
thermostat wiring diagrams.

Instructions for Left or Right Side Wiring

Heater can be wired from either side - wire
one side only.
Cut one factory splice cap as shown.
This leaves two wires for power connection.
Caution: Do not cut both factory splice caps
on left side - you need only two wires for
power connection.

1.

2.
3.
4.

Cut to Apply Power to

LEFT SIDE

Cut to Apply Power to

RIGHT SIDE

Connection Diagram for Wall Thermostat

Connect power supply wires from wall thermo-
stat as shown.
Black and white supply wires can be connected
to the heater in reverse order. For simplicity
the
most common method is shown.
Connect bare groundwire to green groundwire.

1.

2.
3.

4.
5.

Power Supply Connection

LEFT SIDE

Power Supply Connection

RIGHT SIDE

SUPPLY WIRES

HEATER WIRES

SUPPLY WIRES

HEATER WIRES

Connection Diagram for Wall Mounted Single Pole Thermostat
1. Red thermostat wire to black power supply wire.
2. Black thermostat wire to black heater wire.
3. White power supply wire to white heater wire.
4. Connect all bare groundwires together.

BLACK WIRE
RED WIRE
BARE GROUNDWIRE
WHITE WIRE

WIRE COLOR CHART

Connection Diagram for Wall Mounted Double Pole Thermostat

Connect the two red thermostat wires to the black and

white power supply wires.

Connect the two black thermostat wires to the black and

White heater wires.

Connect all the bare groundwires together.

1.

2.

3.

Figure 5

Figure 4

2 1/8"

Element

Air Guide

Self Drilling Screw
or Nail Location

Screwdriver Bit
or Nailing Tool
Location

Limit

Crossover Wire K Series
VOID in CB Series

The CB Series baseboard heater has the return wire within the
element and the wireway is empty, (see Figure 4). If your power
supply is on the right side you will need to cut the loop to apply
your power. If the power supply is on the left, cut one connec-
tor to apply power supply similar to diagram in Figure 5.

CB Ceramic Element Baseboard Heater

K Series Element Baseboard Heater