General operatation, Ekb unit heater, Bracket information – King Electric Model EKB User Manual

Page 2: Turn off circuit breaker to heater

Advertising
background image

General information and Guidelines:

Heater is intended for garage shop and studio heating of large areas from 400 to 1250 square feet depending on your location and

climate. Colder climates require more heat or wattage per square foot than warmer climates. In some cases it may be necessary to

use multiple units to obtain ideal temperature control. If more than one unit is required. Arrange the heaters so they create a circular

air pattern around the outside of the room, or across the coldest walls.

Insulation will aid in retaining heat provided by your new heating system, and will reduce energy costs associated with heating.

The thermostat in the EKB has a range from 40 to 90 degrees with a freeze protection setting of approximately 50 degrees. Freeze

protection temperature is approximate and should be verified with the digital thermometer if is important that freeze protection is

critical or a potential freeze could cause damage. The heater is equipped with a bracket that allows it to be mounted to either the

ceiling or the wall. The heater can then be tilted 25 degrees to direct heated air towards the floor. Never point at the ceiling, toward
other appliances or objects that obstruct the airflow, or toward objects that could be damaged by excessive heat or have the poten-

tial to catch fire due to prolonged exposure to heat. Following these simple guidelines will have provide you with a comfortable safe

heating system for years to come.

Heater inner workings:

The EKB cast aluminum motor incorporates a large oil reservoir that is maintenance free and recirculates the oil across the shaft at a

rate of 5 drops per minute. The motor is Thermally protected for safety. The 80/20 Ni-Chrome elements allow for quick heating and

cooling type leaving all the heat in the room by time the fan stops. A self-holding over-temp limit is provided on each element as well

as one main self holding limit located between the elements for total shut off. If the total heater shut off limit trips the heater is disa-

bled until the power to the heater is shut off for 10 minutes at which point it will reset. There is no fan delay on start up or shut off

so no special complicated feed wiring is required for remote thermostat connections. (i.e. switch loops circuits).

Operation:

The EKB heater requires mounting in a clear, open-air location for optimal performance.

Heater should be installed in a location that is clear and will remain of storage items. The heat outlet of the unit should be able to

push warmed air to the far side of the room. Ample space should be left behind the heater to allow air to be drawn in through the

back of the unit. Clearance recommendations within these instructions are the minimum, providing more space will result in improved

airflow and safer operation.

Maintenance instructions:

Turn off circuit breaker to heater.

Motors are maintenance free and do not need to be oiled. Heater will need to be blown out and cleaned every year, in order to be

kept free of all dust, dirt and fibers that may accumulate. Use compressed air to free up any particles that may have entered the

heater. Fan blades should be clean and able to move freely. Wipe both the front and rear grills and continue to keep clear all debris

and wiped clean with a soft towel.

General Operatation

EKB Unit Heater

2

10 3/8 in / 26.35 cm wide

Heater case size

w/o bracket

Height:13 5/8 in. / 34.6 cm

Width: 10 3/8 in./ 26.35 cm

Depth: 9 3/9 in. / 24.76 cm

Maximum Outside Dims

W/bracket and stat

Height:18 3/4 in / 47.62 cm
Width: 11 3/8 in. / 28.90 cm

Depth: 10 5/8 in./26.98 cm



Hole Sizes
* 1/2” in./1.27 cm 3 Holes
+ 1/4 in. /.63 cm 4 Holes

11” in./27.9 cm

2” in./5.0 cm

6 5/8 in./16.8 cm

8 3/4 in./22.2 cm

+

*

1 1/8 in./2.85 cm

2 1/8 in./5.4 cm

Bracket Information

Fig 2.1

Fig 2.2

*

*

+

+

+

2 3/8 in./6.0 cm

10 1/2 in./27.6 cm

Pivot to top of bracket

King Electrical Mfg. Co. 9131 10th Ave So. Seattle, Wa 98108 206-762-0400 www.king-electric.com