Step 3

Weld the closer housing #2 to the underside of the gate in the correct position giving the

desired clearance between the gate and post. The distance from the face of the post to the

centre of the closer pivot is 4

5

/

16

” (110mm) when gate is in closed position.

Step 4

Weld bottom support #7 to the gate post

Step 5

Weld top pivot #6 to top of gate post