TB-950 Magnum Instructions

4

Lockey® TB-950 Magnum

Concealed, high use, pedestrian gate closer

(with hydraulic controls for closing & latching speed)

Step 7

Mount gate to post

Step 8

Adjust closing speed (hole nearest post) and

latching speed (hole farthest from post)

using 3mm Allen key

Installation Instructions

Step 6

After galvanizing/painting, grease roller

bearing, and replace parts into closer

housing #2 placing the drive plate #5 to the
correct handing and then place a small piece

of adhesive tape across drive plate #5 and

closer housing #2 to secure while mounting

gate

Maintenance

The regularity of maintenance should reflect the frequency of use, environment and the likelihood of van-

dalism or misuse. Should you require more information about gate closer maintenance, please contact

us using the contact information at the bottom of this page.

The following checks and lubrication should be regularly completed:

1)

Check to ensure all fastenings are secure

2)

Check function of closer

3)

Lubricate roller bearing

Disclaimer

LockeyUSA will not accept any responsibility whatsoever for damage caused by incorrect fitting, misuse, or incorrect assessment of the
application. In purchasing this product, the purchaser accepts all responsibility for the installation, operation and maintenance of the
product.