Alto-Shaam Halo Heat 1000-BQ2/128 User Manual

Page 16

Advertising
background image

1000-BQ2

SERIES OPERATION

&

CARE MANUAL

• 14

D A N G E R

DISCONNECT UNIT FROM

POWER SOURCE BEFORE

CLEANING OR SERVICING.

C A U T I O N

THIS SECTION IS PROVIDED FOR THE ASSISTANCE

OF QUALIFIED SERVICE TECHNICIANS ONLY AND

IS NOT INTENDED FOR USE BY UNTRAINED OR

UNAUTHORIZED SERVICE PERSONNEL.

S E R V I C E

T R O U B L E S H O O T I N G - M A N U A L C O N T R O L

Error
Code

Description/Results

Possible Cause
Service Required

E-10

Air Sensor Fault (shorted)

Inoperative Unit

Air sensor is shorted.

Air sensor defective?

Test air sensor by placing sensor in ice water bath 32°F (0°C) and using an

ohmmeter set on the ohm scale. The reading should be 100 ohms resistance. If it

is more than 2 ohms higher or lower, sensor needs to be replaced. If Ohm reading

is 100, replace display. If Ohm reading is not 100, replace sensor.

E-11

Air Sensor Fault (open)

Inoperative Unit

Air sensor is open or connection failure.

Air sensor defective? See above for air sensor test.

E-30

Under temperature

Oven will not reach set temperature

Unit door closed? Door gasket need replacement? Preheat skipped?

Unit overloaded or holding frozen product? Defective air sensor or probe?

Defective solid state relay? Bad wire connections or open heating cable?

If none of the above, contact Alto-Shaam Service Department.

E-31

Over temperature

Unit will shut down

Unit has exceeded its maximum allowable set temperature by 25 degrees for at

least 3 minutes. Unit will shut down.

Defective sensor or poor sensor connection?

Defective relay?

Shorted heater element?

If none of the above, contact Alto-Shaam Service Department.

E-70

Configuration error

Inoperative Unit

Contact Alto-Shaam Service Department for correct DIP-switch settings.

E-82
or
E-83

EEPROM Error - Bad Checksum

Inoperative Unit

Contact Alto-Shaam Service Department for help resetting the control.

E-90

Button shorted

Inoperative Control

Stuck button on control panel. Check buttons.

If control is still inoperative, contact Alto-Shaam Service Department.

E-91

Input failure

Contact Alto-Shaam Service Department.

-AC-

Power Failure

Press any key to acknowledge.

Advertising