1000-BQ2

SERIES OPERATION

&

CARE MANUAL

• 6

1.

An identification tag is permanently mounted on

the cabinet.

2.

Plug cabinet into a properly grounded receptacle

ONLY, positioning the unit so the power supply

cord is easily accessible in case of an emergency.

3.

If necessary, a proper receptacle or outlet

configuration as required for this unit,

must be installed by a licensed electrician

in accordance with applicable, local electrical codes.

NOTE:

230V units:

To prevent an electrical shock hazard between

the appliance and other appliances or metal

parts in close vicinity, an equalization-bonding

stud is provided. An equalization bonding lead

must be connected to this stud and the other

appliances / metal parts to provide sufficient

protection against potential difference. The

terminal is marked with the following symbol.

The appliance must be connected to an

electrical circuit that is protected by an

external GFCI outlet.

D A N G E R

ENSURE POWER SOURCE

MATCHES VOLTAGE STAMPED

ON APPLIANCE NAMEPLATE.

D A N G E R

To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be
made in accordance with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.

D A N G E R

ELECTRICAL CONNECTIONS MUST

BE MADE BY A QUALIFIED SERVICE

TECHNICIAN IN ACCORDANCE WITH

APPLICABLE ELECTRICAL CODES.

ELECTRICAL

• 1000-BQ2/192

VOLTAGE

PHASECYCLE

/

HZ

AMPS

kW

CORD

&

PLUG INCLUDED

120 (

AGCY

)

1

60

NEMA

L5-20

P

POWER SWITCH IN LOW POSITION

16.0

1.9

20A- 125V

PLUG

POWER SWITCH IN HIGH POSITION

24.0

MAX

3.0

NEMA

L5-30

P

30A - 125

V PLUG

208-240 (

AGCY

) 1

60

12.5

3.0

NEMA

6-15

P

at 208

1

60

11.8

2.5

15A - 250V

PLUG

at 240

1

60

13.6

3.3

230 (

AGCY

)

1

50

13.0

3.0

CEE

7/7

220-230V

PLUG

ELECTRICAL

• 1000-BQ2/128

VOLTAGE

PHASECYCLE

/

HZ

AMPS

kW

CORD

&

PLUG INCLUDED

120 (

AGCY

)

1

60

16.7

2.0

NEMA

5-20

P

20A- 125V

PLUG

208-240 (

AGCY

)

1

60

8.7

2.0

NEMA

6-15

P

208

1

60

7.7

1.6

15A - 250V

PLUG

240

1

60

8.9

2.1

230 (

AGCY

)

1 50/60

8.4

2.0

CEE

7/7

220-230V

PLUG

ELECTRICAL

• 1000-BQ2/96

VOLTAGE

PHASECYCLE

/

HZ

AMPS

kW

CORD

&

PLUG INCLUDED

120 (

AGCY

)

1

60

12.8

1.6

NEMA

5-15

P

15A- 125V

PLUG

208-240 (

AGCY

)

1

60

6.7

1.6

NEMA

6-15

P

at 208

1

60

5.9

1.2

15A - 250V

PLUG

at 240

1

60

6.7

1.6

230 (

AGCY

)

1 50/60

6.5

1.5

CEE

7/7

220-230V

PLUG

E L E C T R I C A L C O N N E C T I O N

I N S T A L L A T I O N

Wire diagrams are located inside the top of the unit.