Pxd series digitizer – Teledyne LeCroy PXD Series User Manual
Page 12
Advertising

8
ISSUED: March 2003
901217-01
PXD Series Digitizer
•
Power up the chassis. (If you are connecting to the chassis via an MXI-3 connection, power up
the computer after powering up the chassis.
CAUTION
Overheating will result if any slots in the PXI chassis remain open. Cover all open
slots to ensure proper air flow. Chassis fans should be at maximum speed. Chassis
cooling will vary from manufacturer to manufacturer. A minimum airflow of 5 cfm
through the PXD 212, 512, and 1021; and 15 cfm through the PXD 114, 214, 514, 522,
and 1022 to the Digitizer’s air inlet at a temperature between 0 °C and 40 °C must be
provided.
CAUTION
Static-sensitive parts. Proper handling, including a grounded wrist strap, should be
observed at all times.
Advertising