3 irecoptions::setrecmode, Irecoptions::setrecmode – Teledyne LeCroy Automation API for Bluetooth Analyzers User Manual
Page 58

52
Automation API for CATC Bluetooth Analyzers
CATC
Ver. 1.40
2.5.3 IRecOptions::SetRecMode
Sets the recording mode
Parameters
rec_mode
-
enumerated value providing the mode to set;
ErecModes
enumerator has
the following values:
RMODE_SNAPSHOT
( 0 ) –
snapshot recording mode
RMODE_MANUAL
( 1 ) –
manual trigger
RMODE_USE_TRG
( 2 ) –
event trigger
Return values
E_INVALIDARG
–
invalid recording mode was specified
Remarks
The default setting of recording options is a snapshot recording mode.
Example
WSH:
CurrentDir = Left(WScript.ScriptFullName, InstrRev(WScript.ScriptFullName,
"\"))
Set Analyzer = WScript.CreateObject("CATC.Merlin")
Set RecOptions = Analyzer.GetRecordingOptions
RecOptions.SetRecMode 2' Event trigger
C++:
HRESULT SetRecMode (
[in] ERecModes rec_mode );