3 irecoptions::setrecmode – Teledyne LeCroy SierraFC Automation API User Manual
Page 48
Advertising

LeCroy Corporation
SierraFC M8-4 API Reference Manual
Manual Version 1.00
48
5.1.3 IRecOptions::SetRecMode
HRESULT SetRecMode (
[in] ERecModes rec_mode );
Sets the recording mode.
Parameters
rec_mode
Enumerated value providing the mode to set;
ErecModes enumerator has the following values:
RMODE_SNAPSHOT ( 0 )
snapshot recording mode
RMODE_MANUAL ( 1 )
manual trigger
RMODE_USE_TRG ( 2 )
event trigger
Return values
E_INVALIDARG –
invalid recording mode was specified
Remarks
The default setting of recording options is "snapshot" recording mode.
Example
WSH:
Set Analyzer = WScript.CreateObject("LeCroy.FCAnalyzer")
Set RecOptions = Analyzer.GetRecordingOptions
RecOptions.SetRecMode 2 ' Event trigger
C++: