5.23.2 How to Start or Reset a Timer

You can Start or Reset the Timer in the Global State and in the Sequence State by 
performing the following steps:

1. Open the Recording Rules page, select an event, and drag it to the Global State or 

Sequence cells. For details on these steps (see

 “Events with Channels” on page 96)

.

2. Right‐click on an event and select Specify Actions > Start Global Timer > Global 

Timer A or Timer B from the menu. See the figure below.

Figure 5.47: Starting and Resetting Global and Sequence State Timers

Note:

Listed below are some of the considerations to note about timer functionality

1. If a timer is reset, it will restore to it's original value, in this case the value defined by 

the user.

2. Resetting a timer will stop it and set it to it's original value.
3. Local timers for a particular state will automatically reset if the sequencer advances 

to another state. Example: "Timer A" in State 1 and "Timer A" in State 2 are different 
timers not related to each other.

4. Local timers are controlled by events defined in the same state where the timers are 

defined.