6 iuwbanalyzer::startrecording, Iuwbanalyzer::startrecording – Teledyne LeCroy UWBTracer Automation Manual User Manual
Page 15

LeCroy
UWBTracer Automation API Reference Manual
Manual Version 3.02
11
3.1.6 IUwbAnalyzer::StartRecording
HRESULT StartRecording (
[in] BSTR ro_file_name );
Starts recording with specified recording options.
Parameters
ro_file_name
String providing the full pathname to recording options file; if the
parameter is omitted, then recording starts with default recording
options.
Return values
ANALYZERCOMERROR_UNABLESTARTRECORDING
unable to start recording
Remarks
This function returns after recording starts. The Analyzer continues recording until it finishes or until either
the “StopRecording” or "StopRecordingAndWaitForTrace" method call is performed. During the
recording, the events are sent to event sink (see the _IAnalyzerEvents interface section).
Recording options file is the file with extension .rec created by the UWBTracer application. You can
create such a file when you select Setup – Recording Options… from the UWBTracer application menu,
change the recording options in the dialog, and select the Save button.