Customize Decode Result Table
Follow these steps to change which decode values appear in the result table:
1. Press the Front Panel Serial Decode button, or choose Analysis > Serial Decode, then open the
Decode Setup tab.
2. Touch the Configure Table button.
3. On the View Columns pop-up dialog, check boxes for the columns you want to appear in the table.
Clear boxes for any columns you wish to remove. Only those columns selected will appear on the
oscilloscope display.
To return to the preset display, touch Default.
4. Optionally, set a BitRate Tolerance percentage. This value will allow for signal jitter correction while
decoding.
5. Touch the Close button when finished.
6. Optionally, on the Decode Setup dialog enter the Table # Rows to display. Each row will contain data
from one decoded message.
NOTE: Keep in mind that displaying several, multiple-row tables will reduce the amount of screen
space available for the waveform grids.
You may display or hide these columns on the ENET result table.
Time(us) - Time (in microseconds) of the beginning of the frame, with respect to the trigger time
of the acquisition.
Type - Frame or Idle time.
Dest Addr - Packet destination MAC address.
Source Addr - Packet origination MAC address.
Details - Decoded data (type and payload), or type of protocol error if decode failed.
Section of typical ENET result table.