Plunger pumps, Sj & xj series pumps, Warnings – Vortexx SJ & XJ Series User Manual

Page 4: North america

Advertising
background image

Operating Instructions and Parts Manual

SJ & XJ Series Pumps

Plunger Pumps

First Choice When Quality Matters

NORTH

AMERICA

Formulas

Nozzles:
Impact Force (lbs.) = .0526 x GPM x √PSI
Nozzle # = GPM x 4000
√ PSI
GPM= Nozzle # x PSI
√4000
PSI = (GPM/Nozzle #)

2

x 4000

Horse Power:
GPM x PSI = Hydraulic HP
1714
GPM x PSI = EBHP
1457
EBHP x 1457 = GPM
PSI
EBHP x 1457 = PSI
GPM
HP loss due to altitude = 3% per 1000 FT
above sea level
Pump Speed and Flow:
Rated GPM = Desired GPM
Rated RPM Desired RPM
Motor Pulley Ø = Pump Pulley Ø
Pump RPM

Motor RPM

Conversions

Gallons x 3.785412 = Liters
Gallons x 128 = Oz.
PSI x .06896 = Bar
Bar x 14.5038 = PSI
1 inches = 25.4 millimeters
Liters x .2642 = Gallons (US)
Ft. Lbs. x 1.356 = Newton Meters
Inch Lbs. x .11298 = Newton Meters
Newton Meters x .737562 = Ft. Lbs. (force)
Newton Meters x 8.85 = In. Lbs. (force)
Temperature = 1.8(C° + 17.78) = F°,.555(F°
- 32) = C°
1 U.S. Gallon of freshwater = 8.33 lbs.
1 PSI = 2.31 feet of water
1 PSI = 2.04 inches of mercury
1 Foot of water = .433 PSI
1 Foot of water = .885 inches of mercury
1 Meter of water = 3.28 feet of water
Kilograms x 2.2 = Lbs.

General Safety Information

WARNINGS

Gasoline Drive Pumps

The pump is designed to pump non-
flammable or non-explosive fluids.
These pumps are intended to pump

clean filtered water only.

Do not operate in or around an
explosive environment.

Always wear safety glasses
or goggles and appropriate

clothing.

Do not alter the pump from the

manufacturers design.
Do not allow children to operate

the pump.
Never point the high-pressure
discharge at a person, any part of
the body or animals.
Do not operate gasoline engines in

a confined area; always have adequate
ventilation.
Do not exceed the pump specifications

in speed or pressure.

Advertising