The appliance must be installed by a qualified

service technician. The oven must be properly

grounded in accordance with the National Electrical

Code and applicable local codes.

Plug the unit into a properly grounded receptacle

ONLY, positioning the unit so that the plug is easily

accessible in case of an emergency. Arcing will occur

when connecting or disconnecting the unit unless all

controls are in the “

off

” position.

Proper receptacle or outlet configuration or

permanent wiring for this unit must be installed by

a licensed electrician in accordance with applicable

local electrical codes.

Supply cords used with this equipment shall be

oil-resistant, sheathed flexible cable not lighter

than ordinary polychloroprene or other equivalent

synthetic elastomer-sheathed cord (Code designation

60245 IEC).

REGARDING INTERNATIONAL STANDARD UNITS:
If the unit is not equipped with flexible cord and

plug, an all-pole country approved disconnection

device which has a contact separation of at least 3mm

in all poles must be incorporated in the fixed wiring

for disconnection. When using a cord without a plug,

the green/yellow conductor shall be connected to the

terminal which is marked with the ground symbol.

If a plug is used, the socket outlet must be easily

accessible. If the power cord needs replacement, use

a similar one obtained from the distributor.

E L E C T R I C A L C O N N E C T I O N

I N S T A L L A T I O N

D A N G E R

ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.

D A N G E R

To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical
connections are to be made in
accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.

Wire diagrams are located inside the bonnet of the unit .

ELECTRICAL - 767-SK/III

vOLTaGE

PHaSE

cycLE

/

Hz

aMPS

kW

aWG

208-240

(

agcy

)

1

60

16.0

3.9

cord

,

at 208

1

60

15.5

3.2

no

plug

at 240

1

60

17.9

4.3

230

1

50/60 15.4

3.1

cee

7/7

220-230v

plug

ELECTRICAL - 1767-SK/III

vOLTaGE

PHaSE

cycLE

/

Hz

aMPS

kW

aWG

208-240 (

agcy

) 1

60

32.0

7.7

no

cord

at 208

1

60

31.0

6.5

or

plug

at 240

1

60

35.8

8.6

230

1

50

29.1

6.1

no

cord

or

plug

ELECTRICAL - 1000-SK/III

vOLTaGE

PHaSE

cycLE

/

Hz

aMPS

kW

cOrD

&

PLuG

208-240

(

agcy

)

1

60

15.8 3.8

no

cord

at 208

1

60

14.4

3.0

or

plug

at 240

1

60

16.7

4.0

230

1

50

14.0

2.8

cee

7/7

220-230v

plug

ELECTRICAL - 1200-SK/III

vOLTaGE

PHaSE

cycLE

/

Hz

aMPS

kW

cOrD

&

PLuG

208-240

(

agcy

)

1

60

33.3 8.0

no

cord

at 208

1

60

30.6

6.4

or

plug

at 240

1

60

35.4

8.5

230

1

50

31.5

7.2

no

cord

or

plug

NOTE

:

CE approved appliances must be

connected to an electrical circuit that is

protected by an external GFCI outlet.

Hard wired models:
Hard wired models must be equipped with a

country certified external allpole disconnection

switch with sufficient contact separation.
If a power cord is used for the connection of the

product an oil resistant cord like H05RN or H07RN

or equivalent must be used.

D A N G E R

ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.

For CE approved units: To prevent an electrical

shock hazard between the appliance and other

appliances or metal parts in close vicinity, an

equalization-bonding stud is provided. An

equalization bonding lead must be connected to

this stud and the other appliances / metal parts

to provide sufficient protection against potential

difference. The terminal is marked

with the following symbol.