Operating features & functions – Alto-Shaam 1000-SK/III User Manual

Page 15

Advertising
background image

deluxe

control

smokers

installation

/

operation

/

service

manual

-

pg

. 13

To stop an operation at any time Press and hold

the START Key until the control beeps for two seconds,

indicating the operation has been cancelled. The oven

will remain in a power-on state.
To turn oven control panel off Press and hold

the ON/OFF Key until the oven beeps. The ON/OFF

indicator light will go out.
Door open indicator — Display will flash “door” and

a triple beep will alert the user. Press ON/OFF key to

acknowledge error and disable triple beep.
Arrow Keys:

Cook, Hold and Probe Temperature, and the Time setting

can be adjusted by pressing the Arrow keys. Pressing

and releasing the Arrow key will increase settings in

increments of one. To change a setting more rapidly,

press and hold the Arrow key. Once the setting reaches

a number divisible by 10, it will begin to increase in

increments of 10.
Green and Amber Indicators:

Each program key includes a green

light which indicates a requirement

for additional programming by the

operator or the current operational

state of the oven.
The COOK, TIME, PROB E, and HOLD keys include

an amber indicator light to identify the information

being displayed.
Power Fail Detect:

If the power were to fail for any reason while heating, the

control will retain, in memory, the programmed operating

conditions. When power is restored, the control will

resume operating from the point where it was interrupted

and the ON/OFF indicator light will flash, indicating that

such an event did occur. The operator can acknowledge

the power failure by pressing the ON/OFF key. Pressing

the key will display the amount of time that the power

has been off. The control will stop counting the amount

of time the power has been off when it has been off for

more than 24 hours.
NOTE: If such an event has occurred, it is strongly

recommended that you ensure the food is safe for

consumption according to local health regulations.
Display High/Low Probe Temperatures:

To observe the recorded maximum or minimum probe

temperature when cooking by probe, press the following

keys while the probe remains in the product:
Highest Temperature: Press PROBE Key and UP

ARROW Key at same time.
Lowest Temperature: Press PROBE Key and DOWN

ARROW Key at same time.

Probe Usage:
When the oven probe remains inserted in the probe

bracket, the LED temperature display will indicate the

ambient air temperature inside the oven. To use the

probe for cooking remove it from the bracket and wipe

the full length of the metal probe with a disposable

alcohol pad to clean and sanitize before using.
Only the tip of the probe senses the internal product

temperature; therefore, it is important the tip be placed

correctly in the product for internal temperature accuracy.

Push the probe tip halfway into the product, positioning

the tip at the center of the food mass. When inserting

the probe into solid foods such as meat roast or poultry

breasts, push the probe in from a straight downward

position or in from the side to the center position. If

placing into a semi-liquid or liquid product, the probe

cable must be secured to keep the probe positioned

properly. Do not let the probe tip touch the edges,

bottom or side of a container. Tape the probe cable to the

lip or edge of the container.

Probe Calibration:
1.
To verify product probe calibration, place the probe

in a warm glass of water along with a quality

independent digital thermometer and press the probe

key for five (5) seconds. Compare readings.

2. If calibration is required, the unit must be in the power

up hold mode. From the off state turn the unit on. The

unit will begin to operate in the power up hold mode,

press the probe key for eight (8) seconds until the unit

beeps twice and a temperature is displayed. Adjust the

probe temperature to match the independent probe by

pressing the up or down arrows to increase or decrease

the temperature. Repeat step 1 to verify.

3. Repeat steps 1 and 2 to verify the probe calibration

as necessary.

OPERATING FEATURES & FUNCTIONS

O P E R A T I N G I N S T R U C T I O N S

NOTE: When cooking by probe, insert the probe

into the raw product after the oven has been

preheated.

WAIT ONE FULL MINUTE to allow the probe

temperature to decrease to the internal temperature

of the product. Press the start button to begin

the cooking process after this probe temperature

adjustment period. A false probe reading of the

internal product temperature will cause the oven to

default to a holding temperature.

Amber

Green

Advertising
This manual is related to the following products: