3. PULLZALL TROUBLE SHOOTING

PROBLEM

POSSIBLE CAUSE

CORRECTIVE ACTION


1.1 PullzAll does not

power in or pulls
slowly.


Battery is not fully charged.

Loose connection on Battery
or Motor Terminals.


Charge Battery

Be sure all connections are tight
and clean. Do not let bottom nut
or stud turn while tightening.

Check the speed mode
selected

Change mode as required.

Battery voltage too low due
to Battery deterioration.

Worn Trigger Switch

Worn Brushes/Motor.

Poor Wiring Connections.

Check for loaded condition
whether overloaded.

Replace Battery.


Repair or Replace Switch.

Replace Motor

Check Wiring connections.

Use the unit within the
permissible load limits.


Rope is interfacing with Tie
Rod or other part of PullzAll.


Rewind Rope on Drum so that it is
level and not rubbing on other
parts of PullzAll.


Motor is hot.


Allow PullzAll Motor to cool for
at least 10 minutes between short
pulls. Increase cooling time for
heavy loads or long pulls.


1.2 Noise


Abnormally worn Bushing.

Worn or Broken Gearset.

Motor malfunctioning.


Replace PullzAll.

Replace PullzAll

Replace Motor.

Advertising