CONNECTING THE CONTROL PACK

WARNING

Loose or unsecured power cables can cause

serious injury or death.

1. Attach the wire terminal housing to the motor

terminals on the winch using terminal nuts and
lock washer previously removed.

2. Install the cover plate and fasten with the two

supplied machine screws. Do not over tighten
screws, over tightening could damage the
plastic components.

3. Use the supplied butt splice connector and the

black extension wire to lengthen the contactor
ground wire (see Figure 11).

4. Reconnect the ground cable and small black

wire to winch motor ground. Ensure the
ground wire is securely fastened. Secure
fasteners to specified torque requirements
in torque specification chart found in these
instructions.

5. Carefully inspect electrical cable routing. Is

it neat and tidy? Zip tie and secure electrical
cables. Zip ties should be snug, but not cutting
into wire insulation. Use electrical tape, pieces
of rubber hose or electrical conduit to protect
electrical cables and wire harness where
needed to avoid electrical cable insulation wear
or abrasion.

6. Attach battery cables, red (positive) cable

FIRST, black (negative) second. Install boots
as appropriate to protect connections. Torque
battery terminal fasteners as directed by vehicle
service manual.

7. Make sure to plug in the winch remote and

ensure that drum is turning in the proper
direction when spooling in/out before using in
the field.

8. Installation

complete.