Installation instruction – WARN ZEON CONTROL PACK RELOCATION KIT 31 User Manual
Page 7
 
WARN INDUSTRIES
9 89969A0
INSTALLATION INSTRUCTION
CONNECTING THE CONTROL PACK
WARNING
Loose or unsecured power cables can cause
serious injury or death.
1. Attach the wire terminal housing to the motor
terminals on the winch using terminal nuts and 
lock washer previously removed.
2. Install the cover plate and fasten with the two
supplied machine screws. Do not over tighten 
screws, over tightening could damage the 
plastic components.
3. Use the supplied butt splice connector and the
black extension wire to lengthen the contactor 
ground wire (see Figure 11).
4. Reconnect the ground cable and small black
wire to winch motor ground. Ensure the 
ground wire is securely fastened. Secure 
fasteners to specified torque requirements 
in torque specification chart found in these 
instructions. 
5. Carefully inspect electrical cable routing. Is
it neat and tidy? Zip tie and secure electrical 
cables. Zip ties should be snug, but not cutting 
into wire insulation. Use electrical tape, pieces 
of rubber hose or electrical conduit to protect 
electrical cables and wire harness where 
needed to avoid electrical cable insulation wear 
or abrasion.
6. Attach battery cables, red (positive) cable
FIRST, black (negative) second. Install boots 
as appropriate to protect connections. Torque 
battery terminal fasteners as directed by vehicle 
service manual. 
7. Make sure to plug in the winch remote and
ensure that drum is turning in the proper 
direction when spooling in/out before using in 
the field.
8. Installation
complete.
Figure 10
Cover Plate
Wire Terminal Housing
Figure 11
Ground Wire
Butt Connector
OUT
IN
Figure 12
WARN INDUSTRIES
89969A0 10
INSTALLATION INSTRUCTION
Mounting Hole Drill Template
4.41
(112)
3.70
(94)
Template NOT to scale