Specifications

Input:

CBC-500-90:

120 VAC ± 10%, 50/60 Hz, 1 phase, 250 VA max.

CBC-500-24:

24-30 VAC, 50/60 Hz, 1 phase, 250 VA max.

CBC-550-90:

120/220/240/380/480 VAC ± 10%, 50/60 Hz, 1 phase, 250 VA max.

CBC-550-24:

120/220/240/380/480 VAC ± 10%, 50/60 Hz, 1 phase, 250 VA max.

Output:

CBC-500-90:

0-90 VDC full-wave rectified nominal,
1.0 amp per channel max., 2.0 amps total

CBC-500-24:

0-24 VDC full-wave rectified nominal,
5.0 amps per channel max., 5.0 amps total

CBC-550-90:

0-90 VDC full-wave rectified nominal,
1.0 amp per channel max., 1.2 amps total

CBC-550-24:

0-24 VDC full-wave rectified nominal,
4.0 amps per channel max., 4.0 amps total

Circuit Protection: (fusing)

CBC-500-90:

2.5 amp, 250 V fast-blo, 3AG

CBC-500-24:

6.3 amp, 250 V fast-blo, 5 x 20 mm

CBC-550-90:

1.5 amp, 250 V fast-blo, 3AG

CBC-550-24:

5 amp, 125 V fast-blo, 5 x 20 mm

Switching Inputs: (external to control, supplied by customer)

Three optically isolated, 10-30 VDC:

Channel 1 Input (adjustable voltage applied to channel 1)
Channel 2 Input (adjustable voltage applied to channel 2)
Channel 2 Override Input (full voltage applied to channel 1)
Maximum off-state leakage < 1 mA

Adjustments:

Channel 1 Voltage (via potentiometer)
Channel 2 Voltage (via potentiometer)
Jumper (selects simultaneous or alternate mode)
Frequency Adjustment: 60-400 Hz (via potentiometer)

Ambient Temperature:

-20° to 122°F (-29° to 50°C)

Auxiliary Supply:

12 VDC, 250 mA maximum

Enclosure:

Optional NEMA 13 enclosure available