System Troubleshooting

The chart below will be helpful when attempting to isolate problems which may occur in the control
system. It will also prove helpful when encountering problems during initial system start-up.

Symptom A: No output on either channel upon power-up.

Probable Cause

Solution

Improper wiring

Check wiring and correct if necessary.

No power available

Check that AC power is available to control.

Blown fuse

See Fuse keeps blowing, Symptom C.

Symptom B: Channel 2 activates upon power-up.

Probable Cause

Solution

Improper wiring

Check wiring and correct if necessary.

Faulty input switching circuit

Check that input switching network is providing proper signal.

Symptom C: Fuse keeps blowing.

Probable Cause

Solution

Improper wiring

Check wiring and replace fuse.

Shorted brake/clutch coil

Check coil resistance and replace if necessary.

Fuse too small

Replace with proper fuse.

Improper AC line voltage

Check line voltage and correct if necessary.

Improper magnet voltage

Check magnet voltage rating and replace with correct magnet if necessary.

Symptom D: Magnets do not appear to have enough torque.

Probable Cause

Solution

Magnets incorrectly sized

Verify sizing by repeating the selection process.

Symptom E: Outputs don't switch; Inputs don't switch.

Probable Cause

Solution

Incorrectly wired inputs

Check wiring and correct if necessary.

Faulty switching device

Check for proper operation and replace if defective.

Faulty control

Replace control.

Reorder Information

Model

Part No.

CBC-500-90

6024-448-003

CBC-500-24

6024-448-002

CBC-550-90

6024-448-006

CBC-550-24

6024-448-005

CBC-500 Series Enclosure

6042-101-004

CBC-550 Series Enclosure

6006-101-007