Warner Electric • 800-825-9050

P-272 819-0527 5/12

Specifications

Input:

CBC-700-90:

120 VAC ± 10%, 50/60 Hz

CBC-700-24:

24 VAC ± 10%, 50/60 Hz

Output Voltage:

Steady State:
CBC-700-90:

90 VDC

CBC-700-24:

24 VDC

Overexcitation:

CBC-700-90:

340 VDC

CBC-700-24:

105 VDC

Output Current: (per channel, alternately)

CBC-700-90:

0.5 Amps max.*

CBC-700-24:

3.5 Amps max.

Circuit Protection: (fusing)

CBC-700-90:

1.6 Amp, 250 Volt, 5 x 20 mm, F/A

CBC-700-24:

5 Amp, 250 Volt, 5 x 20 mm, F/A

* Caution: It will not work with the SF1525HT-90

OEX Pulse Duration: (current model–with OEX on/off switch)

700-24 Switch Position

1 & 2

1

2 & 3

2

3 & 4

3

4

700-90 Switch Position

1 & 2

1

2 & 3

2

3

4

All Open

Time (milliseconds)

8

11

15

22

34

50

100

OEX Pulse Duration: (early model–without OEX on/off switch)

Switch Position

1 & 2

1

2 & 3

2

3 & 4

3

4

Time (Milliseconds)

7

10

15

22

34

51

100

anti-Overlap adjustment:

CBC-700-90:

0 - 100 ms

CBC-700-24:

0 - 50 ms

Switching Inputs:

Two optically isolated, 10-30 VDC
Min. and Max. current input 3.1 - 9.5mA
Maximum off-state leakage < 2 mA

ambient Temperature:

0° to 140° F (-18° to + 60° C)

auxiliary Supply:

12 VDC, 250 mA maximum

Enclosure:

Rated NEMA 13 with optional enclosure (P/N 6042-101-004 )

Reorder Information

Model

Part No.

CBC-700-24

6042-448-002

CBC-700-90

6042-448-003

CBC-700-90C

6042-448-013

Enclosure

6042-101-004

Note: CBC-700-90C has a right angle terminal strip and is conformally coated.