Control adjustments – Warner Electric CBC-700 User Manual

Page 5

Advertising
background image

Clutch/

OEX Switch

Overlap Pot

Brake

(CBC-700-90) (CBC-700-90)

Model

Switches On

%

SF/PB-120

1&2

0

SF/PB-170

1&2

0

SF/PB-250

1

5

SF/PB-400

3

20

SF-500

2&3

10

PC/PB-500

2&3

15

SF-650

2

15

PB-650

2

15

SF-825

4

30

SF-825 brg

4

25

PC/PB-825

3

20

SF-1000

4

35

PC/PB-1000

4

30

SF-1225

All open

60

PC/PB-1225

4

40

SF-1525

All open

70

PC/PB-1525

All open

60

EC-375

1

8

EB-375

1

6

EC-475

2&3

12

EB-475

2&3

10

EC-650

2

15

EB-650

2

15

EC-825

4

26

EB-825

3

20

EC-1000

4

30

EB-1000

4

30

EC-1225

All open

60

EB-1225

All open

55

UM/EM-50

1

5

UM/EM-100

2&3

8

UM/EM-180

2&3

8

UM/EM-210

2

20

UM/EM-215

2

20

EP-170

1&2

0

EP-250

1

5

EP-400

3

20

EP-500

2&3

15

EP-825

4

25

EP-1000

4

35

EP-1525

All open

70

AT-25

3

10

AT-55

3

20

AT-115

3

40

Clutch/

OEX Switch

Overlap Pot

Brake

(CBC-700-90) (CBC-700-90)

Model

Switches On

%

SF/PB-120

1&2

0

SF/PB-170

1&2

0

SF/PB-250

1

5

SF/PB-400

3&4

20

SF-500

2&3

10

PC/PB-500

2&3

15

SF-650

2

15

PB-650

2

15

SF-825

3

30

SF-825 brg

3

25

PC/PB-825

3&4

20

SF-1000

3

35

PC/PB-1000

3

30

SF-1225

4

60

PC/PB-1225

3

40

SF-1525

4

70

PC/PB-1525

4

60

EC-375

1

8

EB-375

1

6

EC-475

2&3

12

EB-475

2&3

10

EC-650

2

15

EB-650

2

15

EC-825

3

26

EB-825

3&4

20

EC-1000

3

30

EB-1000

3

30

EC-1225

4

60

EB-1225

4

55

UM/EM-50

1

5

UM/EM-100

2&3

8

UM/EM-180

2&3

8

UM/EM-210

2

20

UM/EM-215

2

20

EP-170

1&2

0

EP-250

1

5

EP-400

3&4

20

EP-500

2&3

15

EP-825

3

25

EP-1000

3

35

EP-1525

4

70

AT-25

3&4

10

AT-55

3&4

20

AT-115

3&4

40

Clutch/

OEX Switch

Overlap Pot

Brake

(CBC-700-24) (CBC-700-24)

Model

Switches On

%

SF/PB-120

1

0

SF/PB-170

1

0

SF/PB-250

1

3

SF/PB-400

2

10

SF-500

2

16

PC/PB-500

2&3

10

SF-650

3&4

18

PB-650

2

16

SF-825

3&4

20

SF-825 BRG

3&4

20

PC/PB-825

3&4

15

SF-1000

3&4

25

PC/PB-1000

3&4

30

PC/PB-1225

3&4

22

SF-1225

3

40

PC/PB-1225

3

38

SF-1525

4

70

PC/PB-1525

3

45

SF-1525 HT

4

80

EC-375

1

5

EB-375

1

5

EC-475

2&3

12

EB-475

2&3

10

EC-650

3&4

15

EB-650

2

15

EC-825

3&4

20

EB-825

3&4

20

EC-1000

3&4

30

EB-1000

3&4

30

EC-1225

3

40

EB-1225

3

40

UM/EM-50

1&2

5

UM/EM-100

2&3

5

UM/EM-180

2&3

5

UM/EM-210

2

8

UM/EM-215

3&4

8

EP-250

1

3

EP-400

2

10

EP-500

2

16

EP-825

3&4

20

EP-825 HT

4

*0

EP-1000

3&4

25

EP-1525

3

70

AT-25

2

4

AT-55

2

6

AT-115

3&4

14

5

Warner Electric • 800-825-9050

P-272 819-0527 5/12

CBC-700-90 (current model)

(with OEX on/off switch)

CBC-700-90 (early model)

(without OEX on/off switch)

CBC-700-24

This is a floating-type control and is not refer-

enced to aC ground. Under no circumstances should any of

the output wire leads be connected to earth or chassis ground

as the unit will be destroyed.

(Example shows 2 & 3 on for 15 ms duration)

OPEN

1

2

3

4

anti-Overlap Time Delay

Potentiometer PI

OEX Duration Settings

*For the units with a shuttle armature, the
overlap setting should be zero (0).

Control adjustments

The duration of the OEX Pulse and Anti-Overlap Time Delay can be optimized to a specific clutch/
brake. The chart above designates switch settings for 90 and 24 VDC Warner Electric clutch/brake
models.