Specifications, Dimensions for panel mounting – Warner Electric CBC-1000 User Manual

Page 6

Advertising
background image

Range: xxx.xxx to xxxxxx

Keyboard

Sealed tactile feel, 18 positions

Program Security

Program LOCK of lines 1 - 34

Control Outputs

Type

8 Solid State, 100 mA sink max.,

24 VDC max.

Serial Interface

Type

RS-422A/485 compatible

Baud Rate

Selectable: 300, 600, 1200, 2400

Parity

Selectable: None, Odd, Even

Data

ASCII

Format

Start bit, 7 bit ASCII data, Parity bit,

Stop bit

I.D. Number

Programmable 0 to 98: Allows

multidrop systems

Diagnostics

Test 0

Keyboard Test

Test 1

Non-Volatile RAM Test

Test 2

Input Test

Test 3

Output Test

Test 4

Display Test

Test 5

Program Memory Test

Test 6

Date Code Test

Test 7

Serial I/O Test

Test 8

Return to Factory Programming

Mechanical

Enclosure

Aluminum extrusion with molded

VALOX bezel. 2.91” high x 5.67” wide x

6.03” deep overall

Weight

2.5 lbs.

Cutout

5.43” ± 0.04” x 2.68” ± 0.03”

Panel Thickness

1/16” to 1/4”

Panel Depth

5.68” minimum

Environmental

Operating Temp.

0° to +50°C (32° to 122°F)

Storage Temp.

-18° to 85°C (0° to 186°F)

Ambient Humidity

90% and noncondensing

Controller Error Codes

Error 2: Low AC Line Voltage

Error 3: Input Frequency too fast

Error 4: Processor time fully utilized

Specifications

Part No.

6060-448-001

Input Power

100 to 130 VAC, 50/60 Hz, 20VA

(200 to 260 VAC selectable)

Auxiliary Supply

12 VDC @ 175 mA

Used for powering encoder, etc.

Main Counter

Range

6 Decade

Reset Input

2 Individual with 6 decade range

Operation

Quadrature

Reset Input

External and front panel

Count Rate

(20 kHz external input frequency)

Batch Counter

Range

6 Decade

Presets

1 with 6 Decade range

Operation

Count UP by detecting Zero Speed

Reset

Through front panel only

Output

Latched, fixed to output terminal 21

Signal A and B Inputs

Input Frequency

DC, 20 kHz quadrature max.

Input Type

Single ended, Current Source

Input Logic

Times 2

Input High Level

3.25 VDC min.

Input Low Level

1.75 VDC max.

Input Impedance

1.0

Ω to common

Input current

3.25 mA steady state

Input Response

10 µs. min high and low time

Control Inputs

Input Frequency

DC to 20 Hz max. each input

Input Type

Single ended, current sinking

Input Logic

Both Edge and Level sensitive

as defined by input use

Input High Level

10 VDC min. to 20 VDC max.

Input Low Level

0 VDC min. to 2 VDC max.

Input Impedance

4.7

Ω pullup to +12 VDC

Input Current

2.5 mA steady state

Input Response

25 ms. make and break time

Display

Decade

7 Decade, 0.6" red LED

Decimal Point

User programmable

4

Warner Electric • 800-825-9050

P-275 • 819-0496

Dimensions For Panel Mounting

RESET

CLEAR

Press

to clear error code

Make panel cutout. Affix adhesive gasket (if required) to panel. Remove

panel straps and slide unit thru cutout. Slide panel straps into enclosure

guides. Thread 5/8” long hex washer head screws into guides using a

3/16” hex driver and tighten securely.

5.43 ± 040

(138 + 1, -0 mm)

allow 0.32” (8mm) each

side between cutouts

2.68

±

.030

(68

+

1,

-0

mm)

5.68

(144 mm)

Advertising