40 Output Clutch Module
Specifications
Inertia–WR
2
(lb. ft.)
Model Size
Voltage DC
Static Torque lb. ft.
Max. RPM
Armatures
Arm. Hub
Shaft
Weight (lbs)
NEMA Frame Size
50
6, 24, 90
16
3600
.007
.002
.001
4.9
56C/48Y*
100
6, 24, 90
30
3600
.018
.003
.002
5.2
56C/48Y**
180
6, 24, 90
30
3600
.018
.003
.002
5.2
182C/143TC
184C/145TC
210
6, 24, 90
95
3600
.181
.021
.017
15.2
213C/182TC
215C/184TC
All dimensions are nominal, unless otherwise noted.
Size
A
B
C
D
E
F
G
H
AA
BB
CC
DD
Max.
Max.
Dia.
Min.
Pilot Dia.
Dia.
Min.
Key
50
5.188
3.125
.156
6.687
3/16 x
1.813
4.500
.625
30°
36
45°
3/16 x 3/16
3/16 x 1-3/8
100
5.188
3.125
.156
6.687
3/16 x
1.813
4.500
.625
30°
36
45°
3/16 x 3/16
3/16 x 1-3/8
180
5.266
3.125
.313
6.687
3/16 x
1.891
4.500
.875
30°
36
45°
3/16 x 3/16
3/16 x 1-3/8
210
7.578
4.609
.313
9.344
1/4 x
2.500
8.500
1.125
25°
36
45°
1/4 x 1/4
1/4 x 2
Typical End View
AA
BB
CC
DD
1/2" NPT
D
C
B
A
F
H
G
E
* For 56C/48Y Frame motors 3/4 HP and smaller the EM-100 size
may be used where extended life is desirable.
** EM-100 size is recommended for motors 1 HP and larger.
For NEMA standard frame sizes, see page 20.
50-40
100-40
180-40
210-40