SFC-650 Clutch Coupling

Drawing I-25728

Flange Mounted

Customer Shall Maintain:

1.

Concentricity of field mounting pilot diameter
with rotor mounting shaft within .006 T.I.R.

2.

Squareness of field mounting face with shaft
within .006 T.I.R. measured at field mounting
bolt circle.

3.

Rotor mounting pilot diameter must be
concentric with shaft within .006 T.I.R.

4.

Armature mounting shaft to be concentric with
rotor mount ing shaft within .006 T.I.R.

Armature Shaft

.500 – 1.625

Rotor Shaft

.500 – 1.625

Static Torque

95 lb.ft.

Maximum Speed

3,600 RPM

Standard Voltage

D.C. 6, 24, 90

Hub View

* Mounting holes are within .010 of true position relative to

pilot diameter.

.656

1

.062

Max.

2.822
2.820

Dia.

4.625

.062

When New

1.812

.578

max.

1

5/16-18

UNC-3A

Reversible

Hub

Min. Running Clearance

4.375 Dia.

6.687

Max.

Dia.

6.500

Dia.

3.500 max.

.937

1.546

3.58/.338 dia. (4) holes equally

spaced on 7.250 dia.*

45°

5.750

Removable plug

in ends for 1/2"

conduit.

6.500

8.000
7.998

3.58/.338 dia.

(4) holes

equally

spaced on
3.688 dia.*

3.750

Field View

(Inside & Outside Mounted)

See page 44 for details

on Bushings.

All dimensions are nominal, unless otherwise noted.