Note:

If you have a Smooth Start UniModule it is

similar to a standard UniModule except
Autogaps™ are eliminated from the armatures and
a compression spring is inserted between the
armatures. This results in the armatures being in
continuous contact with the rotor and brake
resulting in light, continuous drag. This
arrangement eliminates the sudden change in
torque that results when auto-gapped armatures
engage.

No adjustment is required for the life of the unit
unless it is jarred, resulting in the armature being
moved away from the mating surface and cocking
on the spline. If this occurs, a slight pry on the
armature usually gets it back into position.

Enclosed UniModule Option

Vented Warner Electric UniModules and base
assemblies can be oriented as necessary to keep
contaminants from entering the open housing
vents.

If an Enclosed UniModule is required, an optional
Cover Kit, Warner Electric part number
5370-101-076, can be purchased separately to
enclose the open vents in the housing.

Each Cover Kit includes two (2) vent covers and
four (4) screws needed to convert a vented
UniModule to an enclosed design
(non-washdown) as shown in Figure 9.

Figure 9

Note: When using this Cover Kit to enclose the
module the vent covers should be assembled as
the final step.

Mechanical Data

UM-50

UM-100/180

Static Torque - lb. ft.

16

30

Maximum Speed - rpm

3600

3600

Average Weight-lbs.

1020

15.6

18.7

1040

14.0

16.6

2030

18.4

21.7

3040

16.8

19.5

Wt/s have been changed for GEN II

Inertia - WR - lb.ft.

2

Configuration

50

100/180

1020 input

.021

.047

1020 output

.0195

.050

1040 input

.021

.047

1040 output

.0105

.027

2030 input

.021

.048

2030 output

.0195

.050

3040 input

.021

.048

3040 output

.0105

.027

Warner Electric • 800-825-9050

P-273-4 • 819-0528

8