Warner Electric MCS-208 User Manual
Page 4

4
Warner Electric • 800-825-9050
P-276 • 819-9045
DC common or open collector,
NPN transistor to DC common .
Switch or transistor rating –– 20
VDC minimum, 0.02 amps maximum
rating
Adjustments: Front panel
Dancer Position –– Sets dancer
operating position.
Gain –– Controls overall system
response based on change of
dancer input signal.
MCS-208 Remote/Analog Control Module
Part Number: 6910-448-067
Input Power:
26 ± 4 VDC, 0.5 amps maximum
Ambient
Temperature: +32°F to +120°F (0ºC to +49°C)
Outputs:
1-5 ma
4-20 ma*
10-50 ma
1-9 VDC
*NoTe: The standard transducer accepts a 4-20 ma
output.
Fuses:
1/2 amp, fast acting, 250 V
Protection:
Reverse voltage protection on the
DC power connections
Auxiliary
Inputs:
Brake-On –– Applies maximum
output signal (current or voltage)
to the transducer.
Brake-Off –– Applies minimum
output signal (current or voltage).
to the trandsducer.
Switch Inputs can be controlled by
switch closure between input and
DC common or open collector,
NPN transistor to DC common
Switch or transistor rating –– 20 VDC
minimum, 0.02 amps maximum rating
Adjustments: Front panel
Zero Adjust –– Provides for
adjustment of minimum input to
correspond to minimum output level
Torque Adjust/Span –– Provides for
manual adjust when in the manual
mode. Provides for span adjust when in
other modes of operation.
Operating
Modes:
Local Torque Adjust –– Knob on front
panel
Remote Torque Adjust –– Via a remote
potentiometer
Roll Follower –– Using an external
potentiometer
Current Loop –– 1-5 ma, 4-20 ma,
10-50 ma
Voltage Inputs –– 1-9 VDC
Pivot Point Sensors
MCS-605-1, TCS-605-5
Part
Numbers:
MCS-605-1 (single turn): 7330-448-002
TCS-605-5 (5-turn): 7330-448-003
Control
Element:
Precision potentiometer, 1000 ohms
± 5%, 2 watts
Cable:
15 ft. long, shielded, with connector
General:
The tension sensor should be kept
free from foreign material, dust, grease,
and oil.
electro-Pneumatic Transducer
Part Number: 6910-101-066 (includes filter)
Input Signal:
4-20 ma
Output
Range:
0-120 Psig
Supply
Pressure:
20-150 Psig
NoTe: Supply pressure to the transducer must always
be at least 5 Psig above the maximum output pressure
required for the brake.
Temperature
Range:
-20º F to 150º F
Maximum Air
Consumption: 6.0 (SCFH) at 15 Psig