4

Warner Electric • 800-825-9050

P-276 • 819-9045

DC common or open collector,
NPN transistor to DC common .
Switch or transistor rating –– 20
VDC minimum, 0.02 amps maximum
rating

Adjustments: Front panel

Dancer Position –– Sets dancer
operating position.

Gain –– Controls overall system
response based on change of
dancer input signal.

MCS-208 Remote/Analog Control Module

Part Number: 6910-448-067

Input Power:

26 ± 4 VDC, 0.5 amps maximum

Ambient
Temperature: +32°F to +120°F (0ºC to +49°C)

Outputs:

1-5 ma
4-20 ma*
10-50 ma
1-9 VDC

*NoTe: The standard transducer accepts a 4-20 ma
output.

Fuses:

1/2 amp, fast acting, 250 V

Protection:

Reverse voltage protection on the
DC power connections

Auxiliary
Inputs:

Brake-On –– Applies maximum
output signal (current or voltage)
to the transducer.

Brake-Off –– Applies minimum
output signal (current or voltage).
to the trandsducer.

Switch Inputs can be controlled by
switch closure between input and
DC common or open collector,
NPN transistor to DC common

Switch or transistor rating –– 20 VDC
minimum, 0.02 amps maximum rating

Adjustments: Front panel

Zero Adjust –– Provides for
adjustment of minimum input to
correspond to minimum output level

Torque Adjust/Span –– Provides for
manual adjust when in the manual
mode. Provides for span adjust when in
other modes of operation.

Operating
Modes:

Local Torque Adjust –– Knob on front
panel

Remote Torque Adjust –– Via a remote
potentiometer

Roll Follower –– Using an external
potentiometer

Current Loop –– 1-5 ma, 4-20 ma,
10-50 ma

Voltage Inputs –– 1-9 VDC

Pivot Point Sensors
MCS-605-1, TCS-605-5

Part
Numbers:

MCS-605-1 (single turn): 7330-448-002
TCS-605-5 (5-turn): 7330-448-003

Control
Element:

Precision potentiometer, 1000 ohms
± 5%, 2 watts

Cable:

15 ft. long, shielded, with connector

General:

The tension sensor should be kept
free from foreign material, dust, grease,
and oil.

electro-Pneumatic Transducer

Part Number: 6910-101-066 (includes filter)

Input Signal:

4-20 ma

Output
Range:

0-120 Psig

Supply
Pressure:

20-150 Psig

NoTe: Supply pressure to the transducer must always
be at least 5 Psig above the maximum output pressure
required for the brake.

Temperature
Range:

-20º F to 150º F

Maximum Air
Consumption: 6.0 (SCFH) at 15 Psig