Specifications

Model: MCS2000-DRV2 Dual Channel/Dual
Voltage Driver

Part Number: 6910-448-109

Input Voltage: 24 Volts DC or 48 Volts DC, + / - 10%

Output Voltage: 24 VDC or 48 VDC depending on
power supply input voltage.
In Overvoltage mode, output voltage is
limited to 48 volts DC for 30 seconds before
reducing back to 24 VDC.

Output Current: Maximum of 4.5 amps DC per
channel. Overload capacity to 6 amps maximum per
channel for 30 seconds, to be followed by maximum
3 amps for a period of minimum 120 seconds.

Anti-Residual Output: 10% of input power supply
voltage. Adjustable for each channel.
-2.4 volts DC with 24 VDC power supply input
-4.8 volts DC with 48 VDC power supply input

Analog Input Voltage: 0 to 10 Volts DC on Input A
or Input B. When operating with 48 volt DC power,
input of 0 to 5 volts corresponds to 24 Volt DC
output, and from 5 to 10 volts input overvoltage
mode from 24 to 48 volts DC with timed limitation.

Status and Diagnostic Indicators: 2 LED’s on each
channel indicate normal operation and fault
conditions during operation. One Green and one
Red LED.

Protection:

Input: Polarity protected to prevent damage in the
event of inversion of DC power supply voltages.

Output: Short circuit protected during operation
and power up. Output is also protected from
overload conditions. Once short circuit is detected,
drive locks out for 10 msec and resets. After 4
cycles, drive trips out and requires reset.

Reset Mode: Requires power off and then power on
to reset driver.

Wiring: Via 10 position pluggable terminal block.

Operating Temperature: + 104 ° F (40 ° C)

Storage Temperature: -13 ° F to + 131° F

(-25° C to + 55° C)

Enclosure: NEMA 1 (IP 20)

Certifications: CE