Surgical Scrub sink

Two Station

Model 4102

Last Update: 05/31/13

Surgical Scrub Sink is designed for use in health

GUIDE SPECIFICATION

care institutions providing surgeons with a

Provide an Whitehall Two Station Surgical Scrub Sink

convenient sink for pre-op scrub up.

(specify model number and options) 63-1/2” wide.

Fixture is fabricated from heavy gage, type 304

Fixture shall be fabricated from heavy gage,

stainless steel and is seamless welded construction

type 304 stainless steel, with seamless welded

polished to a satin finish. The cabinet interior is

construction polished to a satin finish. Cabinet

sound-deadened with a fire-resistant material. The

interior shall have a sound-deadening, fire-resistant

unit is designed to be installed on the wall using a

material. Cabinet shall also have removable panels

mounting carrier or it can be floor mounted on a

to allow access to water control valves, waste

stainless steel pedestal base.

connections, stops and strainers. Sinks shall have a
sloping bottom to minimize splashing, and a 3” flat

Scrub Sinks are provided with front panels which

strainer drain. Goosenecks shall have a removable 1-

are easily removed for access to the water control

1/2” spray head. Fixture shall have T/P

valves and waste connections. Scrub sinks have a

temperature/pressure balancing mixing valves

sloping bottom surface to minimize splashing and a

which are easily adjustable at the control panels.

1-1/2” OD tailpiece with a 3” flat strainer drain.

Manufacturer shall provide necessary installation

Backsplash has a gooseneck assembly with a

instructions.

1-1/2” spray head that can be removed for
sterilization.

T/P Temperature/Pressure Balancing Mixing
Valve Control
is located on each control panel and
maintains a constant water temperature with a flow
control of 2.5 GPM. This easily adjustable, anti-scald
valve will automatically shut off if the hot or cold
water supply fails.

Water Supply Valves are mechanical pilot type,
actuated by one push of a knee-operated front panel
and turned off by a second push.

Fixture May Show Some Available Options

Please visit www.whitehallmfg.com

for most current specifications.

4102-LFN-PDM

Whitehall Mfg. > P.O. Box 3527 > City of Industry, CA 91744 > (800) 782-7706 > (626) 968-6681 > Fax (626) 855-4862

4102

Surgical Scrub Sinks

Please visit www.whitehallmfg.com
for most current specifications.

Recyclable
Product

Member of
U.S. Green
Building
Council

Complies

with the

following

standards:

®

Advertising
Table of contents