NOTE: Most building codes require 500 Feet per Minute velocity. Exhaust duct is 1 ft

2

. Check

with your local building official for requirements.

Top Middle Bottom

187.5

187.5

93.75

93.75

[57.15]

[57.15]

[28.58]

[28.58]

187.5

187.5

93.75

93.75

[57.15]

[57.15]

[28.58]

[28.58]

189.75

241.5

155.25

181.125

[57.84]

[73.61]

[47.32]

[55.21]

189.75

241.5

155.25

181.125

[57.84]

[73.61]

[47.32]

[55.21]

187.5

187.5

93.75

93.75

[57.15]

[57.15]

[28.58]

[28.58]

189.75

241.5

155.25

181.125

[57.84]

[73.61]

[47.32]

[55.21]

287.25

365.625

235.125

274.3125

[87.55]

[111.44]

[71.67]

[83.61]

189.75

241.5

155.25

181.125

[57.84]

[73.61]

[47.32]

[55.21]

287.25

365.625

235.125

274.3125

[87.55]

[111.44]

[71.67]

[83.61]

287.25

365.625

235.125

274.3125

[87.55]

[111.44]

[71.67]

[83.61]

287.25

365.625

235.125

274.3125

[87.55]

[111.44]

[71.67]

[83.61]

Single

X

Double

X

Switches On

18xx

24xx

32xx

38xx

Exhaust Flow Rates VELOCITY (min. recommended)

X

Triple

X

X

X

X

X

X

X

X

X

NOTE: Figures represent VELOCITY measured at the Grease Filter.

X

X

X

NOTE: All values are FPM [M/Min] unless otherwise noted.

X

X

AVI RECOMMENDED EXHAUST FLOW RATES

The VELOCITY readings above are obtained by holding an anemometer 3” away from the Grease
Filter. Take several readings in different locations across the filters and average the results.