Oven service procedures, Temperature control programming procedure – XLT XD-9006B User Manual

Page 21

Advertising
background image

Technical Support US: 888-443-2751

Technical Support INTL: 316-943-2751

21

Temperature Control Programming Procedure

OVEN SERVICE PROCEDURES

Read the entire instruction before programming.

TIP

Configuration Button Functions
<FUNC> =The new setting of the selected parameter is stored and the

display advances to the next parameter. This is required be

tween each parameter.

UP= Increases the setting of the selected parameter.

DOWN=Decrease the setting of the selected parameter.

1. Open V101 switch for Basic/Advanced Configuration (Figure 1)

 Remove instrument from its case
 Open switch V101
 Verify that jumper J106, is configured as shown
 Re-insert the instrument back in its case

2. Basic Configurations

Using the configuration buttons, scroll through parameter codes,

changing them to match (Table 1)

 After P17 _._._._. Will appear
 Using the configuration buttons scroll to 262 and press <FUNC>

to enter Advanced Configurations

3. Advanced Configuration Procedure

 Using the configuration buttons scroll through parameter codes

changing them to match (Table 2)

4. Close V101 switch after Basic/Advanced Configuration (Figure 1)

 Remove instrument from its case
 Close Switch V101
 Re-insert the instrument back in its case

5. Operating Parameters Procedure (Table 3)

 On the first pass through change nnn to 3111 to unlock the ad

vanced configuration

 Scroll through the parameter codes again and change the nnn to

5 this locks the advanced configuration

 Scroll through the parameter codes again and verify nnn in ON

Ser1

OFF

P1

5˚C/22˚F

P3

0

P4

315˚C/600˚F

P5

reU

P6

4-20

P9

AL1.P

P10

H.A.

P11

nonE

P16

0

P17

SFtA

P18

norL

P19

norL

P24

reU

P25

OFF

P28

0

P29

0n

P30

0

P34

OFF

P36

tn.30

P37

0

P39

n0FL

P41

P.I.d.

P42

10.0

P43

Fn.SP

P44

0

SP

260°C/500°F

SP2

0

nnn

3111/OFF

AL1

315°C/600°F

HSA1

0.1

Pb

5.0

ti

5.00

td

0.00

1P

30.0

rL

204°C/400°F

rH

310˚C/590°F

Grd1

InF

Grd2

InF

OLH

100.00

toL

InF

rnP

InF

Table 3